<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-5070308606485918650</id><updated>2011-11-27T16:50:47.653-08:00</updated><category term='IR100TA'/><category term='IR200 Universal Infrared Gas Analyzer'/><category term='IR400 Infrared Gas Analyzer'/><category term='IR100TB'/><category term='IR100A'/><category term='SG700 Stack Gas Analyzer'/><category term='IR100B Universal Infrared Gas Analyzers'/><title type='text'>Infrared Gas Analyzers</title><subtitle type='html'></subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://infrared-gas-analyzers.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5070308606485918650/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://infrared-gas-analyzers.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>Electronic Gadgets</name><uri>http://www.blogger.com/profile/00468086523287393855</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>4</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-5070308606485918650.post-1318863060536690224</id><published>2009-11-09T14:23:00.000-08:00</published><updated>2009-11-09T14:24:55.715-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='SG700 Stack Gas Analyzer'/><title type='text'>SG700 Stack Gas Analyzer</title><content type='html'>&lt;img src="http://www.yokogawa.com/an/img/sg700/an-sg700-011.jpg" alt="" width="174" /&gt;&lt;br /&gt;&lt;br /&gt;The SG700 Stack Gas Analyzer consists of a non-dispersive infrared gas analyzer using a highly sensitive and stable double beam system and a zirconia or paramagnetic oxygen analyzer. It can simultaneously measure up to 5 components: NOx, SO&lt;sub&gt;2&lt;/sub&gt;, CO&lt;sub&gt;2&lt;/sub&gt;, CO, and O&lt;sub&gt;2&lt;/sub&gt;.&lt;br /&gt;&lt;br /&gt;The use of interference compensation in the analyzing section virtually eliminates the effects of interference from other components. The SG700 features many functions including autocalibration, conversion to O&lt;sub&gt;2&lt;/sub&gt;-based values, averaging, and high/low alarms. It is used for measuring and monitoring emissions from various types of boilers and waste incinerators.&lt;br /&gt;&lt;br /&gt;&lt;h2 class="heading-typeB01"&gt;&lt;span&gt;Features&lt;/span&gt;&lt;/h2&gt;&lt;br /&gt;&lt;table width="91%" height="18%"&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width="2%" height="3%" valign="top"&gt;*&lt;/td&gt; &lt;td width="95%" height="3%"&gt;Simultaneously measure up to five gas components: &lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="2%" height="3%"&gt;*&lt;/td&gt; &lt;td width="95%" height="3%"&gt;Minimize interaction between gases &lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="2%" height="3%" valign="top"&gt;*&lt;/td&gt; &lt;td width="95%" height="3%"&gt;Reliable zirconia oxygen analyzer &lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="2%" height="3%"&gt;*&lt;/td&gt; &lt;td width="95%" height="3%"&gt;A wealth of functions, including self-diagnostic functions which enhance reliability &lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="2%" height="3%"&gt;*&lt;/td&gt; &lt;td width="95%" height="3%"&gt;Wide dynamic range &lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5070308606485918650-1318863060536690224?l=infrared-gas-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://infrared-gas-analyzers.blogspot.com/feeds/1318863060536690224/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://infrared-gas-analyzers.blogspot.com/2009/11/sg700-stack-gas-analyzer.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5070308606485918650/posts/default/1318863060536690224'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5070308606485918650/posts/default/1318863060536690224'/><link rel='alternate' type='text/html' href='http://infrared-gas-analyzers.blogspot.com/2009/11/sg700-stack-gas-analyzer.html' title='SG700 Stack Gas Analyzer'/><author><name>Electronic Gadgets</name><uri>http://www.blogger.com/profile/00468086523287393855</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5070308606485918650.post-7484184748591025669</id><published>2009-11-09T14:22:00.000-08:00</published><updated>2009-11-09T14:23:49.544-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='IR400 Infrared Gas Analyzer'/><title type='text'>IR400 Infrared Gas Analyzer</title><content type='html'>&lt;img src="http://www.yokogawa.com/an/img/ir-gas/ir400/an-ir400-012.jpg" alt="" width="174" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;The IR400 infrared gas analyzer is capable of measuring the concentrations of NO, SO&lt;sub&gt;2&lt;/sub&gt;, CO&lt;sub&gt;2&lt;/sub&gt;, CO, CH&lt;sub&gt;4&lt;/sub&gt; and O&lt;sub&gt;2&lt;/sub&gt; components in sample gas. NO, SO&lt;sub&gt;2&lt;/sub&gt;, CO&lt;sub&gt;,&lt;/sub&gt; CO and CH&lt;sub&gt;4&lt;/sub&gt; are measured by the nondispersion infrared method (NDIR), while O&lt;sub&gt;2&lt;/sub&gt; is measured by the built-in type paramagnetic method sensor or an external mount-type zirconia method sensor. A maximum of 5 components including O&lt;sub&gt;2&lt;/sub&gt; (max. 4 components except for O&lt;sub&gt;2&lt;/sub&gt; measurement) are simultaneously measurable.&lt;br /&gt;&lt;br /&gt;The mass flow type twin detector of high sensitivity and reliability adopted in the infrared ray method detection unit makes the measurement hardly affected by interfering components. In addition, the IR400 includes a microprocessor and has a large-size liquid crystal display, iproviding easy operation, high accuracy and multiple functions.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;h2 class="heading-typeB01"&gt;&lt;span&gt;Features&lt;/span&gt;&lt;/h2&gt;&lt;br /&gt;&lt;table width="100%" border="0"&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td class="font3" width="2%" height="36" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="36"&gt;Simultaneous and continuous measurement of up to 5 components including O&lt;sub&gt;2&lt;/sub&gt; and 4 components selected from among NO, SO&lt;sub&gt;2&lt;/sub&gt;, CO, CO&lt;sub&gt;2&lt;/sub&gt;, and CH&lt;sub&gt;4&lt;/sub&gt;.&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td class="font3" width="2%" height="14" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="14"&gt;The mass flow type twin detector of high sensitivity and reliability minimizes interference from other gas components, ensuring excellent stability.&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td class="font3" width="2%" height="15" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="15"&gt;Incorporating O&lt;sub&gt;2&lt;/sub&gt; correction, average value computing, automatic calibration, one touch calibration, upper/lower limit alarm, remote measurement range changeover, range identification signal output, etc., the analyzer accommodates different application requirements.&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td class="font3" width="2%" height="13" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="13"&gt;Large LCD provides clear indications of all measured components and computed values and easy interactive operation.&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td class="font3" width="2%" height="13" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="13"&gt;Unitized construction of the main body on the 19-inch rack and of the signal input/output terminal module allows easy configuration of a gas analyzer system.&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td class="font3" width="2%" height="13"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="13"&gt;A maximum range ratio of 1:25 is achieved.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br /&gt;&lt;br /&gt;&lt;h2 class="heading-typeB01"&gt;&lt;span&gt;Applications&lt;/span&gt;&lt;/h2&gt;1. Measurement system for combustion exhaust gas from refuse incinerator and boiler&lt;br /&gt;2. Gas from various types of industrial furnaces&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5070308606485918650-7484184748591025669?l=infrared-gas-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://infrared-gas-analyzers.blogspot.com/feeds/7484184748591025669/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://infrared-gas-analyzers.blogspot.com/2009/11/ir400-infrared-gas-analyzer.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5070308606485918650/posts/default/7484184748591025669'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5070308606485918650/posts/default/7484184748591025669'/><link rel='alternate' type='text/html' href='http://infrared-gas-analyzers.blogspot.com/2009/11/ir400-infrared-gas-analyzer.html' title='IR400 Infrared Gas Analyzer'/><author><name>Electronic Gadgets</name><uri>http://www.blogger.com/profile/00468086523287393855</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5070308606485918650.post-3077373782316132628</id><published>2009-11-09T14:20:00.000-08:00</published><updated>2009-11-09T14:22:11.730-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='IR200 Universal Infrared Gas Analyzer'/><title type='text'>IR200 Universal Infrared Gas Analyzer</title><content type='html'>&lt;h2 class="heading-typeB01"&gt;&lt;img src="http://www.yokogawa.com/an/img/ir-gas/ir200/an-ir200-012.jpg" alt="" vspace="30" /&gt;&lt;/h2&gt;&lt;h2 class="heading-typeB01"&gt;&lt;span&gt;Product Information&lt;/span&gt;&lt;/h2&gt;The IR200 infrared gas analyzer is capable of measuring the concentrations of CO&lt;sub&gt;2&lt;/sub&gt;, CO, CH&lt;sub&gt;4&lt;/sub&gt;, SO&lt;sub&gt;2&lt;/sub&gt;, NO and O&lt;sub&gt;2&lt;/sub&gt; components in sample gas. CO&lt;sub&gt;2&lt;/sub&gt;, CO, CH&lt;sub&gt;4&lt;/sub&gt;, SO&lt;sub&gt;2&lt;/sub&gt; and NO are measured by the non-dispersion infrared method (NDIR), while O&lt;sub&gt;2&lt;/sub&gt; is measured by the paramagnetic or zirconia method. A maximum of 4 components including O&lt;sub&gt;2&lt;/sub&gt; (max. 3 components except for O&lt;sub&gt;2&lt;/sub&gt; measurement) are simultaneously measurable.&lt;br /&gt;&lt;br /&gt;A high-sensitivity mass flow sensor is adopted in the detection block for the infrared method. Due to use of a single beam system for measurement, maintenance is easy and excellent stability is ensured for a long period of time. In addition, a microprocessor is built in and a large-size liquid crystal display is provided for easier operation, higher accuracy and more functions.&lt;br /&gt;&lt;br /&gt;This analyzer is thus optimum for combustion control of various industrial furnaces, botanical study and global atmospheric research.&lt;br /&gt;&lt;br /&gt;&lt;h2 class="heading-typeB01"&gt;&lt;span&gt;Features&lt;/span&gt;&lt;/h2&gt;&lt;table width="100%" border="0"&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td class="font3" width="2%" height="33" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="33" valign="top"&gt;Simultaneous measurement of up to 4 components including O&lt;sub&gt;2&lt;/sub&gt; and 3 components selected from among CO&lt;sub&gt;2&lt;/sub&gt;, CO, CH&lt;sub&gt;4&lt;/sub&gt;, SO&lt;sub&gt;2&lt;/sub&gt;, and NO.&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td class="font3" width="2%" height="23" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="23" valign="top"&gt;A unique optics system minimizes drift particularly due to contamination of measurement cell, ensuring excellent long-term stability.&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td class="font3" width="2%" height="15" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="15" valign="top"&gt;The dual cell type of transmission detector minimizes interference from other gas components.&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td class="font3" width="2%" height="13" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="13" valign="top"&gt;Single beam system allows for simple measurement unit construction and requires no adjustment of optical balance, resulting in low maintenance.&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td class="font3" width="2%" height="13" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="13" valign="top"&gt;Large LCD provides easy interactive operation.&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td class="font3" width="2%" height="38" valign="top"&gt;*&lt;/td&gt; &lt;td class="font3" width="98%" height="38" valign="top"&gt;Highly precise zero/span calibration and automatic calibration are available. Self-diagnostic function detects abnormality and displays an error massage.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br /&gt;&lt;h2 class="heading-typeB01"&gt;&lt;span&gt;Applications&lt;/span&gt;&lt;/h2&gt;1. Combustion control of various industrial furnaces&lt;br /&gt;2. Botanical study&lt;br /&gt;3. Global atmospheric research&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5070308606485918650-3077373782316132628?l=infrared-gas-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://infrared-gas-analyzers.blogspot.com/feeds/3077373782316132628/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://infrared-gas-analyzers.blogspot.com/2009/11/ir200-universal-infrared-gas-analyzer.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5070308606485918650/posts/default/3077373782316132628'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5070308606485918650/posts/default/3077373782316132628'/><link rel='alternate' type='text/html' href='http://infrared-gas-analyzers.blogspot.com/2009/11/ir200-universal-infrared-gas-analyzer.html' title='IR200 Universal Infrared Gas Analyzer'/><author><name>Electronic Gadgets</name><uri>http://www.blogger.com/profile/00468086523287393855</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-5070308606485918650.post-2287244585605113430</id><published>2009-11-09T14:17:00.000-08:00</published><updated>2009-11-09T14:20:14.936-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='IR100TB'/><category scheme='http://www.blogger.com/atom/ns#' term='IR100B Universal Infrared Gas Analyzers'/><category scheme='http://www.blogger.com/atom/ns#' term='IR100A'/><category scheme='http://www.blogger.com/atom/ns#' term='IR100TA'/><title type='text'>IR100TA, IR100TB,IR100A, IR100B Universal Infrared Gas Analyzers</title><content type='html'>&lt;img src="http://www.yokogawa.com/an/img/ir-gas/ir100/an-ir100-011.jpg" alt="" width="174" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;The IR100TA and IR100A, dedicated for analysis of either CO&lt;sub&gt;2&lt;/sub&gt;, CO, or CH&lt;sub&gt;4&lt;/sub&gt;, IR100TB and the IR100B, dedicated for simultaneous analysis of CO&lt;sub&gt;2&lt;/sub&gt; and CO, are available. The analyzers are easy to maintain and works steadily over long periods.&lt;/p&gt;  The ideal application of these analyzers are continuous measurement for the control and monitoring of combustion in various industrial furnaces as well as continuous measurement for the study of plants.&lt;br /&gt;&lt;br /&gt;&lt;h2 class="heading-typeB01"&gt;&lt;span&gt;Features&lt;/span&gt;&lt;/h2&gt;&lt;table 0="" width="100% border="&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width="2%" valign="top"&gt;*&lt;/td&gt; &lt;td width="98%"&gt;Two available models: simultaneous dual-gas (CO and CO&lt;sub&gt;2&lt;/sub&gt;) measurement model and single-gas dual-range measurement model&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="2%" valign="center"&gt;*&lt;/td&gt; &lt;td width="98%"&gt;Stable operation over long periods&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="2%" valign="center"&gt;*&lt;/td&gt; &lt;td width="98%"&gt;Influenced less by presence of another interfering gas&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="2%" valign="center"&gt;*&lt;/td&gt; &lt;td width="98%"&gt;Easy maintenance&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="2%" valign="top"&gt;*&lt;/td&gt; &lt;td width="98%"&gt;Wide variety of additional functions: self-diagnosis, simple calibration, automatic calibration, remote switching measuring range, and range identification&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br /&gt;&lt;br /&gt;&lt;h2 class="heading-typeB01"&gt;&lt;span&gt;Applications&lt;/span&gt;&lt;/h2&gt;&lt;table width="100%" border="0"&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width="30%"&gt;Blast furnace&lt;/td&gt; &lt;td width="70%"&gt;CO; 0 to 40%   CO&lt;sub&gt;2&lt;/sub&gt;; 0 to 30%, 0 to 40%, 0 to 50%&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="30%"&gt;Converter&lt;/td&gt; &lt;td width="70%"&gt;CO; 0 to 100%   CO&lt;sub&gt;2&lt;/sub&gt;; 0 to 100%&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="30%"&gt;Electric furnace&lt;/td&gt; &lt;td width="70%"&gt;CO; 0 to 100%   CO&lt;sub&gt;2&lt;/sub&gt;; 0 to 100%&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="30%"&gt;Coke oven&lt;/td&gt; &lt;td width="70%"&gt;CO; 0 to 100%   CO&lt;sub&gt;2&lt;/sub&gt;; 0 to 100%&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="30%"&gt;Cement kiln&lt;/td&gt; &lt;td width="70%"&gt;CO; 0 to 1%, 0 to 5%&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="30%"&gt;Coal kiln&lt;/td&gt; &lt;td width="70%"&gt;CO; 0 to 1%, 0 to 5%&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="30%"&gt;Carbonizing furnace&lt;/td&gt; &lt;td width="70%"&gt;CO&lt;sub&gt;2&lt;/sub&gt;; 0 to 1%, 0 to 2%&lt;/td&gt; &lt;/tr&gt;  &lt;tr&gt; &lt;td width="30%"&gt;Transforming furnace&lt;/td&gt; &lt;td width="70%"&gt;CO&lt;sub&gt;2&lt;/sub&gt;; 0 to 0.5%, 0 to 1%&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/5070308606485918650-2287244585605113430?l=infrared-gas-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://infrared-gas-analyzers.blogspot.com/feeds/2287244585605113430/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://infrared-gas-analyzers.blogspot.com/2009/11/ir100ta-ir100tbir100a-ir100b-universal.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5070308606485918650/posts/default/2287244585605113430'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5070308606485918650/posts/default/2287244585605113430'/><link rel='alternate' type='text/html' href='http://infrared-gas-analyzers.blogspot.com/2009/11/ir100ta-ir100tbir100a-ir100b-universal.html' title='IR100TA, IR100TB,IR100A, IR100B Universal Infrared Gas Analyzers'/><author><name>Electronic Gadgets</name><uri>http://www.blogger.com/profile/00468086523287393855</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry></feed>
